HAMILTON – C1
HIGHLY FUNCTIONAL VENTILATOR (With integrated air compressor inside the machine)
Model: HAMILTON-C1
Brand:Hamilton Medical / Switzerland
Manufactured: Hamilton Medical AG
Certificates: ISO, CE
- Description
Description
General information
HIGHLY FUNCTIONAL VENTILATOR (With integrated air compressor inside the machine)
Model: HAMILTON-C1
Brand: HAMILTON – Switzerland
Manufactured: Hamilton Medical AG
Certificate: ISO, CE
The main machine includes breathing modes:
- Adaptive pressure ventilation with controlled mandatory ventilation / Synchronized controlled mandatory ventilation (APVcmv / (S)CMV+)
- Adaptive pressure ventilation with synchronized intermittent mandatory ventilation / Synchronized intermittent mandatory ventilation plus (APVsimv / SIMV+)
- Combined breathing mode displays parameters and cardiopulmonary resuscitation time (CPR)
- Volume support breathing mode (VS)
- Pressure-controlled ventilation (PCV+)
- Pressure-controlled synchronized intermittent mandatory ventilation (PSIMV+)
- Spontaneous mode (SPONT)
- Adaptive Support Ventilation (ASV)
Small on size, big on performance.
HAMILTON-C1
- Versatile all-rounder
- Offers a wide range of ventilation therapy options,
including adaptive ventilation modes, noninvasive
ventilation and high flow nasal cannula therapy - Designed for challenging environments like
emergency rooms, where the patient’s condition
can change rapidly and easy transportability is a
must
The HAMILTON-C1 is a versatile and feature-richventilator packaged in a compact size. It is theideal companion for all patient groups, includingneonates. The HAMILTON-C1 adapts effortlesslyto a variety of different settings, such as theintensive care unit, emergency ward, recoveryroom or intermediate care, as well as long-termacute care facilities and during intrahospitaltransport.
- Adult, pediatric, and neonatal ventilation
- Noninvasive ventilation and integrated highflow oxygen therapy
- High-performance turbine and battery
- Individualized, lung-protective ventilationmodes ASV® and INTELLiVENT®-
- ASV
- CPR ventilation
- Digital solutions for respiratory care:Hamilton Connect Module and App
Compact and convenient for transport
The high-performance turbine enables the HAMILTON-C1 mechanical ventilator to be completelyindependent from compressed air. Its integrated high-capacity battery allows you to ventilate yourpatients during intrahospital transport and mobilization, without needing an external power source. Thecompact and lightweight design makes handling easier.
For use in any hospital situation, from neonates to adults
In the intensive care unit
The HAMILTON-C1 offers the performance of a high-end ICU ventilator in a compact size:
- State-of-the-art and advanced ventilation modes, including ASV and
- INTELLiVENT-ASV
- Noninvasive ventilation and integrated high flow oxygen therapy
Advanced lung-protective features and option
During intrahospital transport and for mobilization
The HAMILTON-C1 is a reliable companion for intrahospital transport and mobilization:
- High-performance turbine, battery operation, and compact size
- State-of-the-art ventilation modes appropriate for early mobilization of all patient populations
- Wireless connectivity with the Hamilton Connect Module
For long-term acute care
The HAMILTON-C1 can eliminate the need to use multiple ventilators for patients requiring long-termrespiratory support:
- Portability, making it suitable for mobilization
- Different modes and therapies in one device (invasive ventilation modes including ASV andINTELLiVENT-ASV, NIV, and high flow oxygen therapy)
- The Speak Valve option gives tracheostomized patients a voice, and allows them to swallow evenwhile receiving respiratory support from the ventilator
Technical characteristic
Advanced functions can be upgraded later (optional):
- Neonatal ventilator mode (Neonate) from 0.2 kg to 30 kg.
- Duo positive airway pressure (DuoPAP)
- Airway pressure release ventilation (APRV)
- Noninvasive ventilation (NIV)
- Spontaneous/timed noninvasive ventilation (NIV-ST)
- Nasal continuous positive airway pressure (nCPAP)
- Nasal continuous positive airway pressure with pressure support (nCPAP-PS)
- High flow oxygen therapy (HiFlowO2)
- Volume-controlled Intelligent Ventilation mode (INTELLiVENT-ASV)
- Speak valve compatibility for patient with open trachea.
- Connection with information systems.
- Communication port: CO2/Nurse Call/COM1, CO2/SpO2/COM1, CO2/SpO2/Humidifier & COM1
- Control HAMILTON-H900 humidifier through ventilator
- Trend display (1-72h) / Loop (P-V, V-F, V-F)
- Hamilton Connect Wireless Connection Module (WIFI, Bluetooth)
- Backup second battery (operating up to 8 – 9 hours)
- Monitoring SpO2
- Monitoring Capnography (EtCO2) mainstream & sidestream
MONITORING PARAMETERS (Patient Monitoring)
LUNG MECHANICS
- Cstat (mliter/cmH2O)
- P0.1 (cmH2O)
- PTP (cmH2O*second)
- RCexp (seconds)
- Rinsp (cmH2O/(liter/second))
- RSB (1/(liter*min))
PRESSURE
- AutoPEEP (cmH2O)
- PEEP/CPAP (cmH2O)
- Pmean (cmH2O)
- Pinsp (cmH2O)
- Ppeak (cmH2O)
- Pplateau (cmH2O)
- Pprox (cmH2O)
VOLUME
- ExpMinVol or MinVol NIV (liters/minute)
- MVSpont or MVSpont NIV (liters/minute)
- VTE or VTE NIV (mliter)
- VTESpont (mliter)
- VTI or VTI NIV (mliter)
- Vt/IBW or Vt/Weight (ml/kg)
- VLeak (%)
- Mvleak (L/min)
FLOW
- Insp Flow (l/min)
- Exp Flow (l/min)
- Flow (l/min)
- TIME
- CPR timer
- I:E
- fControl (beat/minute)
- fSpont (beat/minute)
- fTotal (beat/minute)
- TI (seconds)
- TE (seconds)
CO2 GAS (Optional)
- FetCO2 (%)
- PetCO2 (mmHg)
- slopeCO2 (%CO2/liter)
- Vtalv (mliter)
- V’alv (liters/minute)
- V’CO2 (mliters/min)
- VDaw (mliter)
- VDaw/VTE (%)
- VeCO2 (mliter)
- ViCO2 (mliter)
BLOOD OXYGEN SATURATION (SpO2) – (Optional)
- SpO2 (%)
- Pulse (1/minute)
- SpO2/FiO2 (%)
- OSI
- PI (%)
- PVI (%)